Latest Version: 1.1.1
This library allows an imp to communicate with other devices via TCP/IP. It requires the use of Wiznet to transmit the packets between devices via Ethernet.
You can view the library’s source code on GitHub.
To use this library, add the following statements to the top of your device code:
#require "ModbusRTU.device.lib.nut:1.0.2"
#require "ModbusMaster.device.lib.nut:1.0.2"
#require "ModbusTCPMaster.device.lib.nut:1.1.1"
#require "W5500.class.nut"
The following instructions are applicable to Electric Imp’s impAccelerator™ Fieldbus Gateway.
This is the main library class. It implements most of the functions listed in the Modbus specification.
Instantiates a new ModbusTCPMaster object. It takes one required parameter: wiz, the Wiznet W5500 object that is driving the Ethernet link, and one optional boolean parameter: debug which, if enabled, prints the outgoing and incoming ADU for debugging purposes. The default value of debug is false
.
// Configure SPI
local spi = hardware.spi0;
spi.configure(CLOCK_IDLE_LOW | MSB_FIRST | USE_CS_L, 1000);
local wiz = W5500(spi, hardware.pinXC, null, hardware.pinXA);
wiz.configureNetworkSettings("192.168.1.30", "255.255.255.0", "192.168.1.1");
// instantiate a modbus object
modbus <- ModbusTCPMaster(wiz);
This method configures the network and opens a TCP connection with the device. It will try to reconnect when the connection is not closed intentionally. It takes the following parameters:
Parameter | Data Type | Required | Default Value | Description |
---|---|---|---|---|
connectionSettings | Table | Yes | N/A | The device IP address and port. The device IP address can either be a string or an array of four bytes, for example: [192, 168, 1, 37] or "192.168.1.37" . The port can either be an integer or array of two bytes (the high and low bytes of an unsigned two-byte integer value), for example: [0x10, 0x92] or 4242 |
onConnectCallback | Function | No | Null | The function to be fired when the connection is established |
onReconnectCallback | Function | No | Null | The function to be fired when the connection is re-established |
Note If an onReconnectCallback is not supplied, when the connection is re-established, the onConnectCallback will be fired.
// The device address and port
local connectionSettings = {
"destIP" : "192.168.1.90",
"destPort" : 502
};
// Open the connection
modbus.connect(connectionSettings, function(error, conn){
if (error) {
server.log(error);
} else {
// do something here
}
});
This method closes the existing TCP connection. It takes one optional parameter, callback, which is a function that will be executed when the connection has been closed.
modbus.disconnect();
Function code: 01, 02, 03, 04
This is a generic method used to read values from a single coil, register, or multiple coils and registers. It has the following parameters:
Parameter | Data Type | Required | Default Value | Description |
---|---|---|---|---|
targetType | Constant | Yes | N/A | Refer to ‘Target Type’ table, below |
startingAddress | Integer | Yes | N/A | The address from which it begins reading values |
quantity | Integer | Yes | N/A | The number of consecutive addresses the values are read from |
callback | Function | No | Null | The function to be fired when it receives response regarding this request. It takes two parameters, error and result |
Target Type | Value | Access |
---|---|---|
Coil | MODBUSRTU_TARGET_TYPE.COIL | Read-Write |
Discrete Input | MODBUSRTU_TARGET_TYPE.DISCRETE_INPUT | Read Only |
Input Register | MODBUSRTU_TARGET_TYPE.INPUT_REGISTER | Read Only |
Holding Register | MODBUSRTU_TARGET_TYPE.HOLDING_REGISTER | Read-Write |
// Read from a single coil
modbus.read(MODBUSRTU_TARGET_TYPE.DISCRETE_INPUT, 0x01, 1, function(error, result) {
if (error) {
server.error(error);
} else {
server.log(result);
}
}.bindenv(this));
// Read from multiple registers
modbus.read(MODBUSRTU_TARGET_TYPE.INPUT_REGISTER, 0x01 , 5, function(error, results) {
if (error) {
server.error(error);
} else {
foreach(key, value in results) {
server.log(key + " : " + value);
}
}
}.bindenv(this));
Function code: 05, 06, 15, 16
This is a generic method used to write values into coils or registers. It has the following parameters:
Parameter | Data Type | Required | Default Value | Description |
---|---|---|---|---|
targetType | Constant | Yes | N/A | Refer to the ‘Target Type’ table, above |
startingAddress | Integer | Yes | N/A | The address from which it begins writing values |
quantity | Integer | Yes | N/A | The number of consecutive addresses the values are written into |
values | Integer, array, bool, blob | Yes | N/A | The values written into Coils or Registers. Please view ‘Notes’, below |
callback | Function | No | Null | The function to be fired when it receives response regarding this request. It takes two parameters, error and result |
Integer, blob and array[integer] are applicable to MODBUSRTU_TARGET_TYPE.HOLDING_REGISTER. Use array[integer] only when quantity is greater than one.
Integer, bool, blob, and array[integer, bool] are applicable to MODBUSRTU_TARGET_TYPE.COIL. Use array[integer, bool] only when quantity is greater than one. The integer value set to coils can be either 0x0000 or 0xFF00. Other values are ignored.
// Write to a single coil
modbus.write(MODBUSRTU_TARGET_TYPE.COIL, 0x01, 1, true, function(error, result) {
if (error){
server.error(error);
} else {
server.log(result);
}
}.bindenv(this));
// Write to multiple registers
modbus.write(MODBUSRTU_TARGET_TYPE.HOLDING_REGISTER, 0x01, 5, [false, true, false, true, true], function(error, results) {
if (error) {
server.error(error);
} else {
foreach(key, value in results) {
server.log(key + " : " + value);
}
}
}.bindenv(this));
Function code: 07
This method reads the contents of eight Exception Status outputs in a remote device. The optional callback function will, if supplied, be fired when a response regarding this request is received. The callback takes two parameters, error and result.
modbus.readExceptionStatus(function(error, result) {
if (error) {
server.error(error);
} else {
server.log(result);
}
}.bindenv(this));
Function code: 08
This method provides a series of tests for checking the communication system between a client (Master) device and a server (Slave), or for checking various internal error conditions within a server. It takes the following parameters:
Parameter | Data Type | Required | Default Value | Description |
---|---|---|---|---|
subFunctionCode | Constant | Yes | N/A | Refer to the ‘Sub-function Code’ table, below |
data | Blob | Yes | N/A | The data field required by Modbus request |
callback | Function | No | Null | The function to be fired when it receives response regarding this request. It takes two parameters, error and result |
Sub-function Code | Value (Hex) |
---|---|
MODBUSRTU_SUB_FUNCTION_CODE.RETURN_QUERY_DATA | 0x0000 |
MODBUSRTU_SUB_FUNCTION_CODE.RESTART_COMMUNICATION_OPTION | 0x0001 |
MODBUSRTU_SUB_FUNCTION_CODE.RETURN_DIAGNOSTICS_REGISTER | 0x0002 |
MODBUSRTU_SUB_FUNCTION_CODE.CHANGE_ASCII_INPUT_DELIMITER | 0x0003 |
MODBUSRTU_SUB_FUNCTION_CODE.FORCE_LISTEN_ONLY_MODE | 0x0004 |
MODBUSRTU_SUB_FUNCTION_CODE.CLEAR_COUNTERS_AND_DIAGNOSTICS_REGISTER | 0x000A |
MODBUSRTU_SUB_FUNCTION_CODE.RETURN_BUS_MESSAGE_COUNT | 0x000B |
MODBUSRTU_SUB_FUNCTION_CODE.RETURN_BUS_COMMUNICATION_ERROR_COUNT | 0x000C |
MODBUSRTU_SUB_FUNCTION_CODE.RETURN_BUS_EXCEPTION_ERROR_COUNT | 0x000D |
MODBUSRTU_SUB_FUNCTION_CODE.RETURN_SLAVE_MESSAGE_COUNT | 0x000E |
MODBUSRTU_SUB_FUNCTION_CODE.RETURN_SLAVE_NO_RESPONSE_COUNT | 0x000F |
MODBUSRTU_SUB_FUNCTION_CODE.RETURN_SLAVE_NAK_COUNT | 0x0010 |
MODBUSRTU_SUB_FUNCTION_CODE.RETURN_SLAVE_BUSY_COUNT | 0x0011 |
MODBUSRTU_SUB_FUNCTION_CODE.RETURN_BUS_CHARACTER_OVERRUN_COUNT | 0x0012 |
MODBUSRTU_SUB_FUNCTION_CODE.CLEAR_OVERRUN_COUNTER_AND_FLAG | 0x0014 |
local data = blob(2);
data.writen(0xFF00, 'w');
data.swap2();
modbus.diagnostics(MODBUSRTU_SUB_FUNCTION_CODE.RESTART_COMMUNICATION_OPTION, data, function(error, result) {
if (error) {
server.error(error);
} else {
server.log(result);
}
}.bindenv(this));
Function code: 17
This method reads the description of the type, the current status, and other information specific to a remote device. The optional callback function will, if supplied, be fired when a response regarding this request is received. The callback takes two parameters, error and result.
modbus.reportSlaveID(function(error, result) {
if (error) {
server.error(error);
} else {
server.log("Run indicator : " + result.runIndicator);
server.log(result.slaveId);
}
}.bindenv(this));
Function code: 22
This method modifies the contents of a specified holding register using a combination of an AND mask, an OR mask and the register’s current contents. The function can be used to set or clear individual bits in the register. It takes the following parameters:
Parameter | Data Type | Required | Default Value | Description |
---|---|---|---|---|
referenceAddress | Integer | Yes | N/A | The address of the holding register the value is written into |
AND_mask | Integer | Yes | N/A | The AND mask |
OR_mask | Integer | Yes | N/A | The OR mask |
callback | Function | No | Null | The function to be fired when it receives response regarding this request. It takes two parameters, error and result |
modbus.maskWriteRegister(0x10, 0xFFFF, 0x0000, function(error, result) {
if (error) {
server.error(error);
} else {
server.log(result);
}
}.bindenv(this));
Function code: 23
This method performs a combination of one read operation and one write operation in a single Modbus transaction. The write operation is performed before the read. It takes the following parameters:
Parameter | Data Type | Required | Default Value | Description |
---|---|---|---|---|
readingStartAddress | Integer | Yes | N/A | The address from which it begins reading values |
readQuantity | Integer | Yes | N/A | The number of consecutive addresses values are read from |
writeStartAddress | Integer | Yes | N/A | The address from which it begins writing values |
writeQuantity | Integer | Yes | N/A | The number of consecutive addresses values are written into |
writeValue | Blob | Yes | N/A | The value written into the holding register |
callback | Function | No | Null | The function to be fired when it receives response regarding this request. It takes two parameters, error and result |
Function code: 43/14
This method lets you read the identification and additional information relative to the physical and functional description of a remote device. It takes the following parameters:
Parameter | Data Type | Required | Default Value | Description |
---|---|---|---|---|
readDeviceIdCode | Constant | Yes | N/A | Refer to the ‘Read Device ID’ table, below |
objectId | Constant | Yes | N/A | Refer to the ‘Object ID’ table, below |
callback | Function | No | Null | The function to be fired when it receives response regarding this request. It takes two parameters, error and result |
Read Device ID Code | Description |
---|---|
MODBUSRTU_READ_DEVICE_CODE.BASIC | Get the basic device identification (stream access) |
MODBUSRTU_READ_DEVICE_CODE.REGULAR | Get the regular device identification (stream access) |
MODBUSRTU_READ_DEVICE_CODE.EXTENDED | Get the extended device identification (stream access) |
MODBUSRTU_READ_DEVICE_CODE.SPECIFIC | Get one specific identification object (individual access) |
Object ID | Category |
---|---|
MODBUSRTU_OBJECT_ID.VENDOR_NAME | Basic |
MODBUSRTU_OBJECT_ID.PRODUCT_CODE | Basic |
MODBUSRTU_OBJECT_ID.MAJOR_MINOR_REVISION | Basic |
MODBUSRTU_OBJECT_ID.VENDOR_URL | Regular |
MODBUSRTU_OBJECT_ID.PRODUCT_NAME | Regular |
MODBUSRTU_OBJECT_ID.MODEL_NAME | Regular |
MODBUSRTU_OBJECT_ID.USER_APPLICATION_NAME | Regular |
modbus.readDeviceIdentification(MODBUSRTU_READ_DEVICE_CODE.BASIC, MODBUSRTU_OBJECT_ID.VENDOR_NAME, function(error, objects) {
if (error) {
server.error("Error: " + error + ", Objects: " + objects);
} else {
local info = "DeviceId: ";
foreach (id, val in objects) {
info += format("[%d] %s, ", id, val.tostring());
}
server.log(info);
}
}.bindenv(this));
The table below enumerates all the exception codes that can be possibly encountered. Refer to the Modbus specification for more detailed description on Modbus-specific exceptions.
Value (Dec) | Description |
---|---|
1 | Illegal Function |
2 | Illegal Data Address |
3 | Illegal Data Value |
4 | Slave Device Fail |
5 | Acknowledge |
6 | Slave Device Busy |
7 | Negative Acknowledge |
8 | Memory Parity Error |
80 | Response Timeout |
81 | Invalid CRC |
82 | Invalid Argument Length |
83 | Invalid Device Address |
87 | Invalid Target Type |
88 | Invalid Values |
89 | Invalid Quantity |
The ModbusTCPMaster library is licensed under the MIT License.