LPS22HB

Latest Version: 2.0.0

The LPS22HB is a MEMS absolute pressure sensor. This sensor features a large functional range (260-1260hPa) and internal averaging for improved precision. You can view its datasheet here.

The LPS22HB can interface over I²C or SPI. This class addresses only I²C for the time being.

You can view the latest version of the library’s source code on GitHub. Click here to see information on other versions of this library

Note This library now uses the new naming scheme, so users of earlier versions should update the library’s name as well as its version.

To add this library to your project, add #require "LPS22HB.device.lib.nut:2.0.0" to the top of your device code

Hardware

To use the LPS22HB, connect its I²C interface to any of your imp module’s I²C buses. To learn which pins provide I²C functionality, please see the imp pin mux in the Electric Imp Dev Center.

The LPS22HB interrupt pin behavior may be configured through this class, but the corresponding imp pin and associated callback are not configured or managed through this class. To use the interrupt pin:

  • Connect the LPS22HB INT_DRDY pin to an imp GPIO pin
  • Configure the imp pin connected to INT_DRDY as a DIGITAL_IN with your desired callback function
  • Use the methods in this class to configure the interrupt behavior as required

Reset

The LPS22HB is not automatically reset when the library class is instantiated. This is so that Electric Imp applications can use the device through sleep/wake cycles without it losing state. To reset the device to a known state, call the softReset() method:

hardware.i2c89.configure(CLOCK_SPEED_400_KHZ);
pressureSensor <- LPS22HB(hardware.i2c89);
pressureSensor.softReset();

Class Usage

Constructor: LPS22HB(impI2cBus[, i2cAddress])

The constructor takes two arguments to instantiate the class: a pre-configured I²C bus and the sensor’s I²C address in 8-bit form. The I²C address is optional and defaults to 0xB8.

#require "LPS22HB.device.lib.nut:2.0.0"

// Non-default 8-bit I2C Address for LPS22HB (SA0 pulled high)
const LPS22HB_ADDR = 0xBA;

hardware.i2c89.configure(CLOCK_SPEED_400_KHZ);
pressureSensor <- LPS22HB(hardware.i2c89, LPS22HB_ADDR);

Class Methods

read([callback])

The read() method returns a pressure reading in hectopascal (hPa) and a temperature reading in Celsius. The reading result is in the form of a table with the fields pressure and temperature. If an error occurs during the reading, the pressure and temperature fields will be null, and the reading table will contain an additional field, error, with a description of the error.

If a callback parameter is provided, the reading executes asynchronously, and the results table will be passed to the supplied function as the only parameter. If no callback is provided, the method blocks until the reading has been taken and then returns the results table.

Asynchronous Example

pressureSensor.read(function(result) {
    if ("error" in result) {
        server.error("An Error Occurred: " + result.err);
    } else {
        server.log(format("Current Pressure: %0.2f hPa, Current Temperature: %0.2f °C",
            result.pressure, result.temperature));
    }
});

Synchronous Example

function hpaToHg(hpa) {
    return (1.0 * hpa) / 33.8638866667;
}

local result = pressureSensor.read();

if ("error" in result) {
    server.error("An Error Occurred: " + result.err);
} else {
    server.log(format("Current Pressure: %0.2f in. Hg", hpaToHg(result.pressure));
}

setMode(mode[, dataRate])

The LPS22HB can be configured in two different reading modes: LPS22HB_MODE.ONE_SHOT or LPS22HB_MODE.CONTINUOUS. In LPS22HB_MODE.ONE_SHOT, a reading will only be taken only when the read() method is called. This is the default mode. In LPS22HB_MODE.CONTINUOUS, a reading frequency must also be selected using the dataRate parameter and when the read() method is called the latest reading will be returned.

The dataRate parameter sets the output data rate (ODR) of the pressure sensor in Hertz. The nearest supported data rate less than or equal to the requested rate will be set and returned by setMode(). Supported data rates are 0 (one-shot configuration), 1, 10, 25, 50 and 75Hz.

local dataRate = pressureSensor.setMode(LPS22HB_MODE.CONTINUOUS, 25);
server.log(dataRate);

getMode()

Returns the LPS22HB_MODE setting of the pressure sensor.

local mode = pressureSensor.getMode();
if (mode == LPS22HB_MODE.ONE_SHOT) {
    server.log("In one shot mode");
}

if (mode == LPS22HB_MODE.CONTINUOUS) {
    server.log("In continuous mode with a data rate of " +
        pressureSensor.getDataRate() + "Hz");
}

getDataRate()

Returns the output data rate (ODR) of the pressure sensor in Hertz.

local dataRate = pressureSensor.getDataRate();
server.log(dataRate);

enableLowCurrentMode(enabled)

The enableLowCurrentMode() method sets the sensor’s resolution mode and takes one required parameter: a boolean enabled. When enabled is true, the low-current mode is enabled and the device minimizes the current consumption. When enabled is false, the device is optimized to lower the noise. This mode should only be changed when the device is in power-down mode (ie. configured in one-shot mode and not taking a reading).

pressureSensor.enableLowCurrentMode(true);

configureDifferentalPressureMode(mode, enabled)

The configureDifferentalPressureMode() method takes two required parameters: a class constant mode and a boolean enabled.

There are two differential pressure modes: LPS22HB_MODE.AUTO_ZERO and LPS22HB_MODE.AUTO_RIF_P. After enabling either of these modes, the first reading taken will be used to set a reference pressure. In LPS22HB_MODE.AUTO_ZERO mode, both the pressure value used for interrupt generation and the pressure reading returned by the read() method will then be determined by subtracting the referencePressure from the measured pressure. In LPS22HB_MODE.AUTO_RIF_P mode, the pressure value used for interrupt generation will be determined by subtracting the referencePressure from the measured pressure. However, the pressure value returned by the read() method will be the measured pressure.

If sensor is configured in one-shot mode, configureDifferentalPressureMode() will take a reading to set the reference pressure. If the sensor is configured in continuous mode, you must wait one reading cycle before the reference pressure is set.

Once a mode is enabled, the sensor will remain in that mode until it is disabled. To disable select the mode and pass false into the enabled parameter.

// Set mode to one-shot
pressureSensor.setMode(LPS22HB_MODE.ONE_SHOT);

// Take a reading
local reading = pressureSensor.read();
server.log(reading.pressure);

// Enable Auto Zero
server.log("----------------------------");
server.log("Enable Auto Zero mode");
pressureSensor.configureDifferentalPressureMode(LPS22HB_MODE.AUTO_ZERO, true);

// Take a couple readings in Auto Zero mode
reading = pressureSensor.read();
server.log(reading.pressure);
imp.sleep(5);
reading = pressureSensor.read();
server.log(reading.pressure);

// Disable Auto Zero mode
server.log("----------------------------");
server.log("Disabling Auto Zero mode")
press.configureDifferentalPressureMode(LPS22HB_MODE.AUTO_ZERO, false);

// Take a reading
reading = pressureSensor.read();
server.log(reading.pressure);

configureLowPassFilter(bandwidth[, reset])

The configureLowPassFilter() method can enable, disable and reset the low-pass filter when the device is in continuous mode. The low-pass filter is disabled by default. This method has one required parameter: a class constant bandwidth (see below) and one optional parameter: reset, a boolean. If the low-pass filter is active, in order to avoid the transitory phase pass true into the reset parameter.

Bandwidth Constant Description
LPF_BANDWIDTH_ODR_20 Device bandwidth of ODR 20
LPF_BANDWIDTH_ODR_9 Device bandwidth of ODR 9
LPF_OFF Low-pass filter disabled, device bandwidth of ODR 2

Example

// Enable Low-pass filter with a bandwidth of ODR/9
pressureSensor.setMode(LPS22HB_MODE.CONTINUOUS, 25);
pressureSensor.configureLowPassFilter(LPS22HB.LPF_BANDWIDTH_ODR_9);
// Disable Low-pass filter
pressureSensor.configureLowPassFilter(LPS22HB.LPF_OFF, true);

configureDataReadyInterrupt(enable[, options])

This method configures the interrupt pin driver for a data-ready interrupt. The device starts with this disabled by default.

Parameters

Parameter Type Default Description
enable Boolean N/A Set true to enable the interrupt pin
options Bitfield 0x00 Configuration options combined with the bitwise OR operator. See the ‘Options’ table below

Options

Option Constant Description
INT_PIN_ACTIVELOW Interrupt pin is active-high by default. Use to set interrupt to active-low
INT_PIN_OPENDRAIN Interrupt pin driver push-pull by default. Use to set interrupt to open-drain
INT_LATCH Interrupt latching mode is disabled by default. Use to enable interrupt latching mode. To clear a latched interrupt pin call getInterruptSrc()

Example

// Enable interrupt, configure as push-pull, active-high.
pressureSensor.configureDataReadyInterrupt(true);

configureThresholdInterrupt(enable[, threshold][, options])

This method configures the interrupt pin driver for an interrupt based on a threshold event. The device starts with this disabled by default.

Parameters

Parameter Type Default Description
enable Boolean N/A Set true to enable the interrupt pin.
threshold Integer null Interrupts are generated on pressure events. The threshold is expressed in hPa
options Bitfield 0x00 Configuration options combined with the bitwise OR operator. See the ‘Options’ table below

Options

Option Constant Description
INT_PIN_ACTIVELOW Interrupt pin is active-high by default. Use to set interrupt to active-low
INT_PIN_OPENDRAIN Interrupt pin driver push-pull by default. Use to set interrupt to open-drain
INT_LATCH Interrupt latching mode is disabled by default. Use to enable interrupt latching mode. To clear a latched interrupt pin call getInterruptSrc()
INT_LOW_PRESSURE Interrupt is disabled by default. Use to enable interrupt when pressure reading is below threshold on the negative side
INT_HIGH_PRESSURE Interrupt is disabled by default. Use to enable interrupt when pressure reading is above threshold on the positive side

Normal Threshold Interrupt Example

// Enable interrupt, configure as push-pull, active-high, latched.
// Fire interrupt if pressure > 1020 hPa
pressureSensor.configureThresholdInterrupt(true, 1020, LPS22HB.INT_LATCH |
    LPS22HB.INT_HIGH_PRESSURE);

Differential Threshold Interrupt Example

// Set interrupt threshold to trigger if pressure reading is more than 15 hpa
// below the reference pressure
local threshold = 15;

// Configure continuous mode
pressureSensor.setMode(LPS22HB_MODE.CONTINUOUS, 1);

// Enable auto zero mode
pressureSensor.configureDifferentalPressureMode(LPS22HB_MODE.AUTO_ZERO, true);

// Enable interrupt, configure as open-drain, active-low, latched
pressureSensor.configureThresholdInterrupt(true, threshold, LPS22HB.INT_PIN_ACTIVELOW |
    LPS22HB.INT_PIN_OPENDRAIN | LPS22HB.INT_LATCH | LPS22HB.INT_LOW_PRESSURE);

getInterruptSrc()

Use the getInterruptSrc() method to determine what caused an interrupt, and clear latched interrupt. This method returns a table with three keys to provide information about which interrupts are active.

Key Description
int_active true if an interrupt is currently active or latched
high_pressure true if the active or latched interrupt was due to a high-pressure event
low_pressure true if the active or latched interrupt was due to a low-pressure event
// Check the interrupt source and clear the latched interrupt
local intSrc = pressureSensor.getInterruptSrc();
if (intSrc.int_active) {
    // Interrupt is active
    if (intSrc.high_pressure) server.log("High Pressure Interrupt Occurred");
    if (intSrc.low_pressure) server.log("Low Pressure Interrupt Occurred");
} else {
    server.log("No Interrupts Active");
}

softReset()

Reset the LPS22HB from software.

pressureSensor.softReset();

getDeviceID()

Returns the value of the device ID register, 0xB1.

Release History

The Electric Imp Dev Center documents the latest version of the library. For past versions, please see the Electric Imp public GitHub repos listed below.

Version Source Code Notes
1.0.0 GitHub Initial release
2.0.0 GitHub Implement low pass filter; minor bug fixes; renamed library file to match new naming conventions

License

The LPS22HB library is licensed under the MIT License.